Cover Image for System.Linq.Enumerable+EnumerablePartition`1[System.Char]

Treatment of Nerve Impulse Data for Comparison with Theory

OAI: oai:digitalcommons.rockefeller.edu:knight_laboratory-1014

Abstract

A procedure is given for the comparison of nerve impulse data with model predictions. This method utilizes information in the nerve impulse train that is ignored by the post-stimulus-onset histogram and thereby gives an improved signal-to-noise ratio. Comparison of observed responses in the Limulus retina with predictions derived from a detailed model gives good agreement.