Abstract
This article introduces the design of split range control and fuzzy logic control for temperature control of the MISO (multiple input single output) water tank scheme. A multiple input single output (MISO) system is considered for the proposed work as most of the practical systems comprise of numerous MISO system. Investigations are conducted on the impact of control parameters, system dynamics and process disturbances. From the simulation outcomes, it is clearly inferred that the fuzzy logic controller outperformed split range control over all parameters.